Problema crítico
Quando você compila designs que contêm PCS 1000BASE-X/SGMII função, o software Quartus II exibe o seguinte aviso Mensagens:
Critical Warning: "mixed_port_feed_through_mode" parameter
of RAM atom altera_tse_mac_pcs_pma_gige:altera_tse_mac_pcs_pma_gige_inst|altera_tse_mac_pcs_pma_strx_gx_ena:altera_tse_mac_pcs_pma_strx_gx_ena_inst|altera_tse_top_1000_base_x_strx_gx:top_1000_base_x_strx_gx_inst|altera_tse_top_sgmii_strx_gx:U_SGMII|altera_tse_top_rx_converter:U_RXCV|altera_tse_a_fifo_24:U_DSW|altera_tse_sdpm_altsyncram:U_RAM|altsyncram:altsyncram_component|altsyncram_q2e1:auto_generated|ram_block1a8 cannot
have value "old" when different read and write clocks are used.
Critical Warning: "mixed_port_feed_through_mode" parameter of RAM
atom altera_tse_mac_pcs_pma_gige:altera_tse_mac_pcs_pma_gige_inst|altera_tse_mac_pcs_pma_strx_gx_ena:altera_tse_mac_pcs_pma_strx_gx_ena_inst|altera_tse_top_1000_base_x_strx_gx:top_1000_base_x_strx_gx_inst|altera_tse_top_sgmii_strx_gx:U_SGMII|altera_tse_top_rx_converter:U_RXCV|altera_tse_a_fifo_24:U_DSW|altera_tse_sdpm_altsyncram:U_RAM|altsyncram:altsyncram_component|altsyncram_q2e1:auto_generated|ram_block1a7 cannot
have value "old" when different read and write clocks are used.
Você pode ignorar com segurança as mensagens de aviso.
Este problema afeta todos os designs que contêm 1000BASE-X/SGMII Função PCS.
Nenhuma solução alternativa. Este problema será corrigido em uma versão futura da função Ethernet MegaCore de velocidade tripla.